Battery connector
Specifications:
Mechanical characteristics | ||
Items | Test Condition | Performance |
Durability | Apply pressure at the top of the terminal contact, press down 1.5-2.0mm and test 5000 times at 10 tests per minute. |
No reduction in electrical performance. |
Normal Force | Apply force from the top of the terminal contact and depress it vertically by 1.5mm. | Strength:: Terminal A 400 ± 100, Terminal B 200 ± 50 |
erminalRetention Force | Apply force in the opposite direction of the terminal and pull at 25 ± 3 mm per minute | The intensity of the smallest 2N (0.2KGF) No deformation, no loss |
Electrical characteristics | ||
Items | Test Condition | Performance |
Contact resistance | Measure the resistance between the contact apex and the PCB pad at 20mv and 100mA. | 30mΩ MAX. |
Insulation resistance | Apply a DC 250V1 minute voltage test between adjacent terminals and between the terminals and the housing | 50MΩ MIN. |
Withstand voltage | A DC voltage of 250 V for 1 minute was applied between adjacent terminals. |
No breakdown occurs. Leakage current is less than 5mA |
Voltage |
30V RMS |
|
Current |
3A RMS |
|
Operating temperature | -55℃~85℃ |
Note: If the description of the same with the recognition of the specification parameters, the picture is different, have admitted that the book shall prevail.